Out Of Stock
Notify me when its in stockCapacity :3000 g
Minimum Weight : 0.3 g
Units: g – ml - oz
Timer
Display: 4 Digit LED
Maximum Counting Time: 99 minutes 59 seconds
Power Source: 4.5 V 3*AAA Battery
Automatic Shut-off: 2 minutes
Usage:
1 - Press the ‘ON/OFF’ button to display 'HELLO' on the screen. Once stabilized, '0.0' g will be shown on the screen.
2 - Place items on the weighing surface to weigh.
3 - If the display unit is incorrect, press the "UNIT" button to perform unit conversion and select the unit you want to use.
Tare Function:
1. Place a tray or container on the weighing area.
2. Press the "TARE" button, "0.0"g will be displayed on the screen.
3. You can then add products into the container or on the weighing plate.
4. When the container and its contents are removed, ' – ' will be displayed.
Timer Function:
1. Press the "START/STOP" button to start the timer.
2. Press the "START/STOP" button to pause the timer. Press the "START/STOP" button again to resume the timer.
3. Press and hold the "START/STOP" button to reset the timer.
How to brew with coffee scale:
1. Press the "ON/OFF" button to turn on
2. Please place the container and filter on the scale.
3. Press the "TARE" button, "0.0"g will be displayed on the screen.
4. Add ground coffee beans.
5. Press the ‘TARE’ button, "0.0"g will be displayed on the screen.
6. Start the timer and pour hot water.
7. Wait 30 seconds before the next pour.
8. Press the ‘TARE’ button, "0.0"g will be displayed on the screen.
9. Slowly start adding more water.
10. Press the "On/Off" button to end the brewing, which takes 3 minutes.
Warning:
Overload warning: If 'EEEE' appears on the screen, do not weigh heavy objects in a wide range.
Low battery indicator: 'low', please replace with a new battery.
Instability indicator: 'unSt' keep the scale stable to start.
Handling precautions: This is a precision instrument, please do not drop it and avoid strong impacts. It may cause product malfunction.
- Place objects to be weighed gently on the weight platform, dropping products may cause malfunctions.
- Do not place or load anything on the weight platform when storing the product. It may cause malfunctions.
- Please use the product on a flat and stable surface that does not slip. An unstable surface can lead to incorrect weight display or the scale falling.
- Do not place in areas exposed to high temperatures. High temperatures can cause product surface deterioration or fire, please avoid placing the product near stoves, other heating devices, and direct sunlight.
- Mobile radio frequency communication devices may affect electronic scale measurements. Avoid strong electromagnetic interference such as mobile phones, microwave ovens, etc., when in use. It may cause malfunctions.
- Do not use the product if it is heated, disassembled, modified, or immersed in water, as this may cause malfunctions.
Warning for Battery Usage:
Do not short-circuit, disassemble, heat, or throw batteries into a fire. It will lead to overheating, leakage of battery solution, or explosion.
Keep batteries out of reach of children. In case of swallowing, consult a doctor immediately.
If alkaline solution leaks from batteries onto the skin or clothing, wash thoroughly with clean water. If the solution gets into the eyes, wash with clean water and consult a doctor immediately.
When disposing or storing batteries, please insulate them with tape or other methods. Contact with other metals or batteries may cause fire or explosion.
Precautions for Battery Use:
Please follow the instructions below. If batteries are misused, it may cause leakage or explosion of battery solution and result in product malfunction and injury.
Ensure the poles (+/-) are facing the correct directions.
Please remove old batteries from the product as soon as possible.
If the product will not be used for a long time, please remove the batteries
Package/Box : 1/40
Box Size : 35x45x33 cm