ProductFeatures
Depth(cm)
4.2
Height (cm)
27.2
Width (cm)
8.3
Weight
0.39

Testo 816-1 Noise Level Measurement Device

  • Can perform precise measurements between 30 and 130 dB.

  • In frequency analysis, switching between A and C characteristics can be done with a single button.

    • A characteristic: Measures the sound frequency perceived by the human ear.

    • C characteristic: Covers low-frequency sounds.

  • Complies with IEC 61672-1 Class 2 and ANSI S1.4 Type 2 standards.

  • Can store approximately 31,000 measurement records in its memory.

  • Recorded measurement values can be viewed on the device without a computer using the "RECALL" button.

  • Measurement records that can be controlled on a computer with the "REC" button and on the device with the "MEM" button are taken.

  • Fast (125 ms) and slow (1 sec) response modes can be switched using the FAST/SLOW button.

  • Can be connected to a computer with a USB cable for data transfer and device control.

  • Has a low battery indicator, visually alerting the user when the battery is about to run out.

  • Thanks to the illuminated wide LCD screen, measurement results can be easily read even in dark environments.

  • With the Max/Min feature, the highest and lowest sound values measured can be displayed.

  • The device can be easily calibrated with the calibration screw on the side using the screwdriver included in the box.

  • The box includes 1 Testo 816-1 device, 4 AA batteries, a carrying case, wind protection, a PC software CD, a USB cable, a calibration screwdriver, a user manual CD, and a spare connector.

How to Delete Measurement Records on the Device?

Deleting Analysis Records on the Computer:

  • While the device is off, press and hold the "REC + POWER" buttons together.

  • The display will show "Clr Sure 5".

  • Without releasing the buttons, wait until the countdown reaches "SURE 0".

  • Once the process is complete, the display will only show "Clr" and the device will return to the main measurement screen.

Deleting Records on the Device:

  • While the device is off, press and hold the "RECALL + POWER" buttons together.

  • The display will show "Clr Sure 5".

  • Without releasing the buttons, wait until the countdown reaches "SURE 0".

  • Once the process is complete, the display will only show "Clr" and the device will return to the main measurement screen.

TECHNICAL SPECIFICATIONS

  • Measurement Range: 30 - 130 dB

  • Sensitivity: 1.4 dB (under reference conditions: 94 dB, 1 kHz)

  • Frequency Range: 20 Hz - 8 kHz

  • Display Resolution: 0.1 dB

  • A/C Frequency Weighting

  • Time Weighting: Fast 125 milliseconds / Slow 1 second

  • AC Measurement Range: 1 V RMS across the entire scale

  • DC Measurement Range: 10 mV/dB

  • Measurement Frequency: 0.5 seconds

  • Memory Capacity: 31,000 units

  • Power Source: 4 AA batteries

  • Operating Temperature: 0 degrees Celsius - +40 degrees Celsius

  • Storage Temperature: -10 degrees Celsius - +60 degrees Celsius

  • Weight: 390 grams